Hi!
There is a potential buffer overrun when copying FLIBS into words since
FLIBS may be larger than 1024 chars.
This fix applies cleanly to master.
I have a corresponding fix for AmberTools17 if needed, which also fixes
a similar problem with fields in split. There may be more than 256
fields :-)
--
Ake Sandgren, HPC2N, Umea University, S-90187 Umea, Sweden
Internet: ake.hpc2n.umu.se Phone: +46 90 7866134 Fax: +46 90-580 14
Mobile: +46 70 7716134 WWW: http://www.hpc2n.umu.se
_______________________________________________
AMBER-Developers mailing list
AMBER-Developers.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber-developers
Received on Thu Feb 28 2019 - 04:30:02 PST