The test failed. Thanks for pointing it out.
It's not so much a new hydrogen as one in the wrong place. There are two making third bonds to an oxygen. And that's just the beginning of the problems. I'll write Wei.
:-) Lachele
Dr. B. Lachele Foley
Complex Carbohydrate Research Center
The University of Georgia
Athens, GA USA
lfoley.uga.edu
http://glycam.ccrc.uga.edu
________________________________________
From: B. Lachele Foley
Sent: Wednesday, January 19, 2011 8:24 PM
To: AMBER Developers Mailing List
Subject: RE: [AMBER-Developers] Amber test concerns
There have been a number of major changes lately with sleap. The tests might not be keeping up. Our group is testing the changes now. So far, they're looking good. As soon as we lay off Wei for a day or two, he'll probably fix the tests. I'll be sure to give that test a thorough check, tho. Is this behavior different on x86_64 than elsewhere?
:-) Lachele
Dr. B. Lachele Foley
Complex Carbohydrate Research Center
The University of Georgia
Athens, GA USA
lfoley.uga.edu
http://glycam.ccrc.uga.edu
________________________________________
From: Jason Swails [jason.swails.gmail.com]
Sent: Wednesday, January 19, 2011 6:12 PM
To: AMBER Developers Mailing List
Subject: [AMBER-Developers] Amber test concerns
Hello,
I've tested both Amber and AmberTools from a recent git checkout and I've
summarized what I think the major issues are below:
Linux x86_64:
AmberTools (serial):
sleap/glycam && ./Run.test1 -- n.pdb is completely different now, and
there's another proton attached somewhere as well. Is this an intentional
change?
Amber (serial):
sander_pbsa_ipb2 && ./Run.110D.min -- some numbers are significantly
different, but it may be benign
rism3d/ala && ./Run.ala.hnc && ./Run.ala.pse1 -- exits in error with sander
printing the message [ ERROR> solvcut must > 0. ]
Amber (parallel, 2 threads):
All sander.RISM.MPI tests failed with the message [ Fatal error in
MPI_Comm_rank: Invalid communicator, error stack: ]
All EVB tests failed with the error messages:
rank 1 in job 616 Batman_45773 caused collective abort of all ranks
exit status of rank 1: killed by signal 11
rank 0 in job 616 Batman_45773 caused collective abort of all ranks
exit status of rank 0: killed by signal 9
(This has been happening for a long time with the EVB tests -- even with the
Amber 11 release)
I'll follow up with relevant (different) Mac OS X failures later.
All the best,
Jason
--
Jason M. Swails
Quantum Theory Project,
University of Florida
Ph.D. Graduate Student
352-392-4032
_______________________________________________
AMBER-Developers mailing list
AMBER-Developers.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber-developers
_______________________________________________
AMBER-Developers mailing list
AMBER-Developers.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber-developers
Received on Wed Jan 19 2011 - 20:00:04 PST