(Forgive me if you've seen this before, my email setting was messed up so
that many mails went into some kind of /dev/null)
Hi,
We have found a workaround of a bug in mm_pbsa of amber10. This bug was
reported by Gianluca Degliesposti to amber mailing list: PB's ECAVITY
term would have been scaled twice if MS was set to 0. Following the hint
in the GB part of the mm_pbsa script, the surface tension should be
set to 1.0.
This patch has been tested in the original amber10+bugfix1-25. (Note:
test case 04_MMPBSA_Nmode/ras_raf_II_wt_statistics.out.dif failure is
expected.)
Best,
--
Mengjuei Hsieh, Molecular Biology & Biochem, Univ. of California Irvine.
_______________________________________________
AMBER-Developers mailing list
AMBER-Developers.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber-developers
Received on Fri Nov 13 2009 - 15:30:03 PST